Bookmark : https://www.netafim.co.za/products-and-services/nmc-pro-irrigation-controller/?id=95&entryId=87
Skip to : [Content] [Navigation]

Products


NMC PRO Irrigation Controller

NMC PRO Irrigation Controller

Netafim’s NMC Pro irrigation process controller gives you outstanding control

  • More advanced applications.
  • Irrigation by Solar radiation.
  • Dual EC, pH.
  • Pre EC Control.
  • Drainage monitor.
  • NMCnet software flexibility – up to 100 controllers, (50 Irrigation plus 50 Climate) can be connected in a network and presented in the same PC software.
  • User-friendly design – Large graphic backlit LCD display (16 lines x 40 characters) and tactile feel keyboard.
  • Alarm/event logbook.
  • Robust structure – Withstands tough climates.

  Hardware Features

  • CPU Card
  • BUS Board
  • Power Supply
  • Communication Card (RS 485)
  • Memory backup key
  • Internal surge protection
  • 24 VAC Transformer – 80 VA
  • Power requirements – 230 VAC, 50 Hz, 1 Amp
  • Modular system with the following I/O options:
    • Auxiliary 24 VAC Output Terminal.
    • Up to 64 outputs (8 outputs each card), 24 VAC or Dry Contact, with build-in relays for protection.
    • Up to 16 digital inputs (8 inputs each card)
    • Up to 22 analogue inputs (11 inputs each card)

Program features

Details

Triggers for Irrigation

  • Time

 

  • Condition

 

  • Radiation sum

 

  • VPD - vapour pressure deficit

 

Programs

  • Pump program

1 to 6 pumps in parallel

  • Irrigation programs

15

  • Number of simultaneous irrigation programs

1

  • Priority

 

  • Water run time programs

60

  • Dosing programs

10

  • EC Pre-control program (one per dosing program)

10

  • Drainage program

8

  • External condition programs

15

  • Agitator programs

1

  • Filter flushing programs

1

  • Cooling / Humidifying programs - dynamic

8

  • Misting programs

40

  • Water heating programs - On/Off (irrigation water)

1

Other

  • Maximum irrigation controllers in a network

50

  • PC Link (Central software)
 
  • Water run time options

Time / Quantity

  • Dosing channel options

Passive, EC, Acid, Alkali

  • Water systems (pump, filter, dosing stations)

1

 

Outputs

Details

  • Auxiliary 24 VAC output terminal

 

  • Pumps

6

  • Main valves (one active at a time)

6

  • Filters

24

  • Main Filter Valve

1

  • Irrigation Valves

60

  • Misting Valves

40

  • Cooling Valves (10 per program)

16

  • Alarm

1

  • Water Heater

1

  • Dosing Channels

8

  • Dosing Booster

1

  • Agitator

3

  • Selector

7

  • EC Pre-Control Valve - OPEN

1

  • EC Pre-Control Valve - CLOSE

1

  • EC Pre-Control - PUMP

1

  • Condition Active #

15

  • Same As Relay
 

 

Digital Inputs

Details

  • External Pause

1

  • Dosing Booster Protection

1

  • Water Meters

6

  • Dosing Meters

8

  • Auxiliary Meters

8

  • Drain Meter

8

  • Delta Pressure Input

1

  • Dry Contacts (Condition Program)

16

  • Fresh Tank Empty

1

  • Drain Tank Empty

1

  • Rain Collector (Weather Station + Logging)

1

  • Wind Speed (Weather Station + Logging)

1

  • Reset Alarm

1

  • External Alarm 1-3 (Pop-up + Logging)

3


Analogue Inputs

Details

  • pH Sensor

1

  • pH Sensor Verify

1

  • EC Sensor

1

  • EC Sensor Verify

1

  • EC Sensor - Pre EC

1

  • Analogue Pressure - OUT (Low Pressure)

1

  • Analogue Pressure - IN (High Pressure)

1

  • Radiation Sensor - Davis

1

  • Radiation Sum Sensor - Netafim

1

  • Wind Direction

1

  • Temperature Sensors - Outside

1

  • Temperature Sensors - Cooling (per program)

2

  • Temperature Sensors - Heating

2

  • Relative Humidity (RH%) Sensors - Outside

1

  • Relative Humidity (RH%) Sensors - Cooling (per program)

2

    • Limit on the total of all temperature sensors combined

8

    • Limit on the total of all humidity sensors combined

8



Note:

  • The NMC Pro can have up to 10 "Input / Output" cards installed, see slots 1 to 10 below
    • Slots 1 to 5 are allocated for 24 VAC output cards (8 x Outputs per card)
    • Slots 6 and 7 are allocated for input cards (8 x digital) or (11 x analogue)
    • Slots 8 and 9 are allocated for inputs [(8 x Digital) or (11 x Analogue)] or [ 8 x Dry Contacts ]
    • Slot 10 is allocated for one [8 x Dry Contacts] card.
  • Irrigation and climate are different controllers



Downloads

Technical Manual: 

Ask the Expert

Request More Information





Staff login