NMC Junior Climate Controller

NMC Junior Climate Controller

Netafim’s NMC Junior process controller gives you outstanding control

  • More advanced applications.
  • A wider choice of operations.
  • Makes previously complex processes simple and easy to use.
  • NMCnet software flexibility – up to 100 controllers, (50 Irrigation plus 50 Climate) can be connected in a network and presented in the same PC software.
  • User-friendly design – Large graphic backlit LCD display (16 lines x 40 characters) and tactile feel keyboard.
  • Alarm/event logbook.
  • Robust structure.

 Hardware Features

  • CPU Card
  • Power Supply
  • Communication Card (RS 485)
  • Memory backup key
  • Internal surge protection
  • 24 VAC Transformer – 50 VA
  • Power requirements – 230 VAC, 50 Hz, 1 Amp
  • Fix Inputs and Outputs:
    • Auxiliary 24 VAC Output Terminal
    • 15 Outputs 24 VAC with build-in fuses and relays for protection
    • 6 Digital Inputs
    • 5 Analogue Inputs

 Notes:

  • Irrigation and Climate are two different controllers.
  • This is a one Climate Compartment controller.

Program features

Details

Climate Programs

  • Vents

7

  • Wind programs - vents (configuration)

4

  • Fan operation (groups/stages)

4

  • Heating (On/Off) with day and night temperature settings

4

  • Screens - Control by temperature or radiation

2

  • CoolNet program (fogging) - Active window

1

  • CoolNet Program (fogging) - Curve points

4

  • Cool pad (pad and fan) - Active window

1

  • Cool pad (pad and fan) - Curve points

4

  • Misting program

40

  • Circulating fans (groups/stages)

4

Climate Process Programs

  • Humidity treatment (de-humidifying)

4

  • Special ventilation

4

  • CO2 program

1

  • Emergency program (high wind, close vents, start fan)

1

  • Fresh air treatment

4

Other

  • Maximum climate controllers in a network

50

  • PC Link (Central software)
 
  • Climate compartments

1

 

Outputs

Details

  • Auxiliary 24 VAC output terminal

 

  • Wet wall/Pad pumps

1

  • CoolNet valves (foggers)

4

  • Misting valves

15

  • Vents (curtains) - OPEN or CLOSE, not OPEN and CLOSE

7

  • Fan groups

4

  • Screens - OPEN / roll-up

2

  • Screens - CLOSE / spread

2

  • Circulating fans

4

  • Heaters - (On / Off)

4

  • Alarm

1

  • CO2 valve

1

 

 

Inputs

Details

Inputs - Digital

  • Rain Collector

1

  • Rain Sensor (Detector NO / NC contacts)

1

Inputs - Analogue 

  • CO2 Sensor

1

  • Maximum Temperature Sensors
2
  • Relative Humidity (RH%) Sensors - Inside

1

 

NMC Junior has fixed I/O's:

  • 15 x Outputs
  • 6 x Digital Inputs
  • 5 x Analogue Inputs

 

 




Downloads

Ask the Expert

Request More Information





Staff login