NMC 64 Climate Controller

NMC 64 Climate Controller

Netafim’s NMC 64 process controller gives you outstanding control

  • More advanced applications.
  • A wider choice of operations.
  • Makes previously complex processes simple and easy to use.
  • NMCnet software flexibility – up to 100 controllers, (50 Irrigation plus 50 Climate) can be connected in a network and presented in the same PC software.
  • User-friendly design – Large graphic backlit LCD display (16 lines x 40 characters) and tactile feel keyboard.
  • Alarm/event logbook.
  • Robust structure – Withstands tough climates.

 Hardware Features

  • CPU Card
  • BUS Board
  • Power Supply
  • Communication Card (RS 485)
  • Memory backup key
  • Internal surge protection
  • 24 VAC Transformer – 80 VA
  • Power requirements – 230 VAC, 50 Hz, 1 Amp
  • Modular system with the following I/O options:
    • Auxiliary 24 VAC Output Terminal.
    • Up to 64 outputs (8 outputs each card), 24 VAC or Dry Contact, with build-in relays for protection.
    • Up to 16 digital inputs (8 inputs each card)
    • Up to 22 analogue inputs (11 inputs each card)

 Notes:

 Each controller can manage a maximum of 10  “I/O” Cards according to pre-defined parameters.

  • Irrigation and Climate are two different controllers.
  • This is a one Climate Compartment controller.

 

 

Program Features

Details

Climate Programs

  • Vents

16

  • Wind programs - vents (configuration)

4

  • Fan operation (groups/stages)

4

  • Heating (On/Off) with day and night temperature settings

4

  • Screens - Control by temperature or radiation

2

  • CoolNet program (fogging) - Active window

1

  • CoolNet Program (fogging) - Curve points

4

  • Cool pad (pad and fan) - Active window

1

  • Cool pad (pad and fan) - Curve points

4

  • Misting program

40

  • Circulating fans (groups/stages)

4

Climate Process Programs

  • Humidity treatment (de-humidifying)

4

  • Special ventilation

4

  • CO2 program

1

  • Emergency program (high wind, close vents, start fan)

1

  • Fresh air treatment

4

Other

  • Maximum climate controllers in a network

50

  • PC Link (Central software)
 
  • Climate compartments

1

 

Outputs

Details

  • Auxiliary 24 VAC output terminal
 
  • Pad pumps

1

  • CoolNet valves (foggers)

4

  • Misting valves

30

  • Vents (curtains) - OPEN or CLOSE, not OPEN and CLOSE

16

  • Fan groups

4

  • Screens - OPEN / roll-up

2

  • Screens - CLOSE / spread

2

  • Circulating fans

4

  • Heaters - (On / Off)

4

  • Alarm

1

  • CO2 valve

1


Description

Details

Inputs - Digital

 

  • Rain Collector

1

  • Rain Sensor (Detector NO / NC contacts)

1

  • Wind Speed

1

Inputs - Analogue

 

  • Radiation Sensor - Davis

1

  • Radiation Sum Sensor - Netafim

0

  • Wind Direction

1

  • CO2 Sensor

1

  • Maximum temperature sensors

8

  • Relative Humidity (RH%) Sensors

8